Belzona Helps Rebuild End Cooler Headers
Problem
Severe pitting, corrosion appeared on the covers after years of operation. The worst of the pitting was about 8mm deep.
Industry
Application Date
July 2018
Equipment Application
CEP-Centrifugal Pumps (CEP)
Customer Location
Ontario
Substrate
Cast Iron
Products
Belzona 1511 (Super HT-Metal)
Before

Internal surface before application
During

Internal surface showing severe pitting & corrosion damage

Belzona 1511 application, the product is being applied
After

Completed application

Application Situation
End cooler headers of a tube sheet. Design temperature: 200F.

Application Method
Application was carried out in accordance with Belzona Know-How System Leaflets CEP-5 & FBC-5. Belzona 1511 was used to rebuild the entire profile of the inside of the cooler heads.

Belzona Facts
The water collectors originally had no lining and were severely damaged after years of service. The Belzona solution restored the equipment thickness, preventing future corrosion and extending the useful life of the equipment.
Manufacturing replacement heads would take over a year; however, with the use of Belzona they repaired the equipment and returned to service after a couple of weeks avoiding prolonged downtime.
Contact us
In Belzona Great Lakes, we have made it our mission to be an indispensable asset to our customers.
Our experienced Technical Consultants have a solid history of quality applications and offer personal attention and guidance every step of the way.
They diagnose the problem, recommend the Belzona solution, and supervise the application. They diagnose the problem, recommend the Belzona solution, and supervise the application.
Contact your nearest Consultant and schedule a free evaluation!