Repair And Coating for a Boiler Feed Pump
Problem
After 3 to 4 months in use the boiler feed pump was suffering from general corrosion/erosion and the metal shavings in the feed eventually would lead to a through hole in the casing.
Industry
Application Date
December 2012
Equipment Application
CEP-Centrifugal Pumps (CEP)
Customer Location
Windsor, Ontario
Substrate
Steel
Products
Belzona 1391 (Ceramic HT)
Before

Boiler feed pump prior to application
During

Preparation completed

Application completed
After

Fifteen months after application

Application Situation
Boiler feed pump.

Application Method
Application was carried out in accordance with Belzona Know-How System Leaflet CEP-5 for repair of general erosion damage. The surface was prepared by grinding the entire surface to be coated. Belzona 1391 was applied with a stiff bristle brush as a two coat system in accordance with the Belzona Instructions For Use.

Belzona Facts
Belzona 1391 has been designed to operate under continuous immersion of temperatures up to 120°C (248°F) as the boiler feed was working at a temperature of 93°C (200°F). Fifteen months (March 2014) after application the system is in great working order with no corrosion/erosion or holes.
Contact us
In Belzona Great Lakes, we have made it our mission to be an indispensable asset to our customers.
Our experienced Technical Consultants have a solid history of quality applications and offer personal attention and guidance every step of the way.
They diagnose the problem, recommend the Belzona solution, and supervise the application. They diagnose the problem, recommend the Belzona solution, and supervise the application.
Contact your nearest Consultant and schedule a free evaluation!