Pipe Strengthening with Belzona SuperWrap II

Problem

A 60” carbon steel pipe that had suffered from external corrosion and metal loss over the years. The defective area was about 15 feet. They required a solution that would reinstate the structural integrity of the pipe.

Industry

Facilities Maintenance

Application Date

2020

Location

Toronto / Canada

Equipment Application

VPF-Valves, Pipes and Fittings

Subtrate

Carbon Steel

Product

Belzona 1121 (Super XL-Metal)
Belzona 1982
Belzona SuperWrap II

Repair Stages

Application Situation

We used ASME PCC2 equations to estimate the number of wraps required to retrofit the pipe to design conditions. The defect was type A (thin wall), corrosion was external, and the pressure was relatively low (25 psi). 2 wraps of Belzona SWII were recommended to structurally reinforce the pipe and effectively stop corrosion on the pipe. This repair system can remain maintenance-free for up to 20 years.

Application Method

First, the pipe was grit blasted and prepared according to SSPC SP10. All the pitting and resurfacing was then done with Belzona 1121(Super XL-Metal) because of its longer overcoating time. The next day, they started applying Belzona SWII. They applied the wrap in 4 feet sections at a time, so every 4 feet they would consolidate the repair with Belzona 9382 and continue with the next section. Though the application was during colder climate, Belzona 1982 was chosen to give more working life and allow the crew to complete the application properly.

Belzona Facts

Customer received an ISO/ASME compliant repair system able to stop the corrosion, return the mechanical strength back to the water pipe and designed to provide a 20 year lifetime.

Contact your nearest Belzona Consultant and schedule a free evaluation!

Other Cases

Pipe Strengthening with Belzona SuperWrap II

A 60” carbon steel pipe that had suffered from external corrosion and metal loss over the years. The defective area was about 15 feet. They required a solution that would reinstate the structural integrity of the pipe.

Leak Repair at Pickling Line

Hydrochloric acid tank in a Pickle line was suffering from chemical attack and developed a leak. They needed a product that had excellent chemical resistance against Hydrochloric acid at high concentrations to stop this leak and protect the outside of the tank.