Problem

White cement was falling off from a gap between the silo cone and the concrete wall which poses safety concerns for the employees.

Industry

Mining & Quarrying

Application Date

2024

Location

Ontario / Canada

Equipment Application

RPA-Roof Problem Areas

Subtrate

other

Product

Belzona 1121 (Super XL-Metal)
Belzona 9111 (Cleaner Degreaser)
Injection Pistol

Repair Stages

Application Situation

Customer needed a material that would bond to both steel and cement to seal the gap between the silo cone.

Application Method

A blower was used to used remove cement from the surface and surroundings. Belzona 91111 was used to clean the surfaA blower was used to used remove cement from the surface and surroundings. Belzona 91111 was used to clean the surface. Belzona 1121 was then injected using Belzona pneumatic pistol into the gap to seal off the falling materials. Additional material was applied using Belzona applicator to make sure the area is well sealed.

Belzona Facts

Product cured on multiple substrate and the gap was sealed. After 24 hours, an inspection by the production team coProduct cured on multiple substrate and the gap was sealed. After 24 hours, an inspection by the production team confirmed that materials were no longer falling from the gap hereby confirming a perfect seal. Customer is looking at sealing up such gaps with Belzona in the nearest future.

Contact your nearest Belzona Consultant and schedule a free evaluation!

Other Cases

Repair And Coating for a Boiler Feed Pump

After 3 to 4 months in use the boiler feed pump was suffering from general corrosion/erosion and the metal shavings in the feed eventually would lead to a through hole in the casing.

Petrochemical Flange Encapsulation

Customer based in Sarnia, Ontario was having corrosion problems in several flanges of his plant. The protective paint that was used in the past would peel off, exposing the substrate, which lead to corrosion around the flange, studs and nuts.