CASE

Leaking Porous Weld Repair

Problem

Weld Joint on stainless steel pipe was leaking due to a porosity and slag inclusion.

Industry

Water & Wastewater Management

Application Date

2021

Location

Ontario / Canada

Equipment Application

VPF-Valves, Pipes and Fittings

Subtrate

Stainless Steel

Product

Belzona 1111 (Super Metal)
Belzona 9111 (Cleaner Degreaser)

Repair Stages

Application Situation

The asset owner required a weld joint on the city water tower S/S filling pipe to be repaired without performing hot work and also required a NSF approved product.

Application Method

Preparation was completed in-way of using a grinder with a 80 grit sanding pad, than cleaned with Belzona 9111. Next the Belzona 1111 repair composite was mixed and applied well into the preferred area. Using a piece of Belzona 9341 Reinforcing cloth was wetted out and applied over the repair area with a further layer of Belzona 1111 until the cloth was covered.

Belzona Facts

Sub-Contractor contacted Belzona Great Lakes to discuss solutions the BGL would suggest to be used for this type of repair and also mentioned that a approved NSF-61 product was required.

Contact your nearest Belzona Consultant and schedule a free evaluation!

Other Cases

Protection of Wastewater Centrifuge

The centrifuge was suffering from erosion-corrosion and scale buildup. They needed a product that would protect the equipment but also help reduce the buildup and improve the efficiency of the equipment.